Solenoid Coils

Goyen Replacement Solenoid Coils

This page currently lists one replacement solenoid coil for Goyen-style pilot valves: the K0301, rated 120 V AC with a DIN socket connection. A burned-out or open coil is a common reason a single pulse valve stops firing while the rest of the collector keeps working. Swapping the coil is often quicker and cheaper than replacing the whole pilot.

Before ordering, confirm that your pilot runs on 120 V AC and uses a DIN-style plug connector. If your system uses another voltage, or if the coil is built into an RCA3PV pilot, look at the pilot coil kits in the Pilot Repair Kits category. Those cover 12 V DC through 220/240 V AC. Complete pilots are listed under Pilot Valves.

Not sure which coil you have? Send us the markings on the old coil or the pilot model number. Industrial Filtration has supplied dust collector filters and parts since 1956, and we can usually identify the part from a photo or a tag. Call 562-436-4228 or email info@industrialfiltrationinc.com for a quote.

Goyen is a trademark of its owner. Parts listed are replacements unless otherwise noted.

Showing the single result