Product Type: Bulkhead Connector

Style: Two dresser nuts (BHDD)

Base Model: BH20DD

Nominal Pipe Size: 20 mm (3/4")

Material: Diecast aluminium & nitrile

Sealing Material: Nitrile

Temperature Range: -40°C to 80°C (-40°F to 176°F)

Mounting Hole Diameter: 45 – 51 mm (1.75 – 2.0")

Overall Length (L): 52 mm (2.05")

Insertion Depth (D): 48 mm (1.89")

Dimension B: 97 mm (3.81")

Unit Mass: 0.41 kg (0.90 lbs)

Arrangement: Suits separate inboard and outboard blowtubes

Suitable For: Most reverse pulse jet dust collector installations and their variations including bag filters, cartridge filters, envelope filters, ceramic filters and sintered metal fibre filters

SKU BH20DD Category

Description

This replacement Goyen BH20DD Bulkhead Connector was designed to the same specifications and is guaranteed to fit/perform as well as the OEM

*All filters and items marked replacement are not affiliated or associated with the original manufacture. Part numbers and names are used for cross reference only.

All valve and repair kits are backed by a 100% money back guarantee against defects in materials and workmanship. In the event of a product failure, we will replace the affected kit at no additional cost.

For Genuine Goyen Valves and Parts please call 562-436-4228 or email us at info@industrialfiltrationinc.com

Aluminium diecast bulkhead connector that mounts a Goyen cleaning system and blowtube onto a dust collector wall without welding. Two dresser nuts design (BHDD), suiting separate inboard and outboard blowtubes, for 20 mm (3/4") nominal pipe with a nitrile seal.

Bulkhead connectors let the blowtube and valve assembly be removed for maintenance without cutting or rewelding. Cut a mounting hole of 45 – 51 mm (1.75 – 2.0") and allow 97 mm (3.81") for dimension B.

Mating valve clearances:

Mating valve C E
CA/RCA20DD 22 mm (0.86") 105 mm (4.13")
CA/RCA20T 7 mm (0.28") N/A
CA/RCA20FS 34 mm (1.34") 66 mm (2.60")

Important: dresser nut and slide seal assemblies are for sealing purposes only and are not intended for valve or blowtube restraint. Blowtubes and valves must be independently restrained. Do not pressurise the system until all valves are fully secured, and fully relieve pressure before working on any cleaning system component.

Other sealing materials:

Viton: Goyen BH20DD-V Bulkhead Connector

Matching wall seals:

Reviews

There are no reviews yet.

Be the first to review “Goyen BH20DD Bulkhead Connector – Two Dresser Nuts – 20 mm (3/4″) Pipe – Nitrile”

contact us

Products

search

Industrial Filtration Inc logo

Request A Quote

To request a quote, enter the filter part #, along with a brief description of what you are looking for (optional), then hit 'Request quote'. Thank you for the opportunity to quote.

or try to find it on our website