Description
This replacement Goyen 3-8V3016-330 Pilot Valve Enclosure was designed to the same specifications and is guaranteed to fit/perform as well as the OEM
*All filters and items marked replacement are not affiliated or associated with the original manufacture. Part numbers and names are used for cross reference only.
All valve and repair kits are backed by a 100% money back guarantee against defects in materials and workmanship. In the event of a product failure, we will replace the affected kit at no additional cost.
For Genuine Goyen Valves and Parts please call 562-436-4228 or email us at info@industrialfiltrationinc.com
Diecast aluminium NEMA 4 / raintight enclosure for Goyen RCA3D pilot valves, housing up to 8 pilots and supplied with 3 fitted. Pilot thread 1/8" NPT, conduit entry M25, 3/4" NPT or 3/4" G, 220/240 V AC 50/60 Hz QT2 solenoids, Goyen nameplate. The enclosure arrives pre-wired with common solenoid terminals, so field wiring is a single run to the conduit entry rather than one per pilot.
Fitted with a 100/120 v ac 50/60 hz anti-condensation heater. Note: the C-Tick, CE, CSA, UL and ATEX approvals listed do not apply once a heater or slave card is installed.
Suitable for ATEX Category Ex II 3 GD and IP65 service and all other non-hazardous applications. Keep the supply voltage within -10% and +15% of the rated solenoid voltage. Recommended on time is 50 – 500 ms with at least 1 minute between pulses.
Installation: disconnect the device from power before opening the enclosure. To guarantee NEMA 4 performance make sure the gasket is in place when refitting the lid to the base.
Spare parts:
- Goyen K0380 Pilot Repair Kit – nitrile replacement seal, armature, spring and ferrule kit
- Goyen K0384 Pilot Repair Kit – the same kit in Viton
- RCA3D0-*** and RCA3D1-*** replacement pilot assemblies, listed separately under Goyen RCA3 pilot valves