Description
This replacement Goyen BH40D Bulkhead Connector was designed to the same specifications and is guaranteed to fit/perform as well as the OEM
*All filters and items marked replacement are not affiliated or associated with the original manufacture. Part numbers and names are used for cross reference only.
All valve and repair kits are backed by a 100% money back guarantee against defects in materials and workmanship. In the event of a product failure, we will replace the affected kit at no additional cost.
For Genuine Goyen Valves and Parts please call 562-436-4228 or email us at info@industrialfiltrationinc.com
Aluminium diecast bulkhead connector that mounts a Goyen cleaning system and blowtube onto a dust collector wall without welding. Single dresser nut design (BHD), suiting a single blowtube passing straight through the collector wall, for 40 mm (1.5") nominal pipe with a nitrile seal.
Bulkhead connectors let the blowtube and valve assembly be removed for maintenance without cutting or rewelding. Cut a mounting hole of 72 – 78 mm (2.8 – 3.1") and allow 157 mm (6.19") for dimension B.
Mating valve clearances:
| Mating valve | C | E |
|---|---|---|
| CA/RCA45DD | 40 mm (1.57") | 155 mm (6.10") |
| CA/RCA45T | 16 mm (0.63") | N/A |
| CA/RCA45FS | 88 mm (3.46") | 96 mm (3.78") |
Important: dresser nut and slide seal assemblies are for sealing purposes only and are not intended for valve or blowtube restraint. Blowtubes and valves must be independently restrained. Do not pressurise the system until all valves are fully secured, and fully relieve pressure before working on any cleaning system component.
Other sealing materials:
Viton: Goyen BH40D-V Bulkhead Connector
Matching wall seals:



Reviews