Description
This replacement Goyen VNA62I-50 Blowtube Nozzle was designed to the same specifications and is guaranteed to fit/perform as well as the OEM
*All filters and items marked replacement are not affiliated or associated with the original manufacture. Part numbers and names are used for cross reference only.
All valve and repair kits are backed by a 100% money back guarantee against defects in materials and workmanship. In the event of a product failure, we will replace the affected kit at no additional cost.
For Genuine Goyen Valves and Parts please call 562-436-4228 or email us at info@industrialfiltrationinc.com
Strapless GOCO nozzle assembly for 2.5" Schedule 40 blowtube with a short barrel. No clamp or strap wraps the tube – the insert hooks through the blowtube hole and the nozzle screws down onto it, which is what makes this range work on the larger 2" to 4" tubes where a strap becomes unwieldy.
A GOCO nozzle balances the flow through every hole along the blowtube and aims the pulse jet squarely into the filter, so the pressure drop through the blowtube holes stops eating the pulse. That lets the system run at an An/Ap ratio (total blowtube hole area to blowtube cross section) of up to 1.5, where a blowtube with plain drilled holes typically manages only 0.5 to 0.8 – which is the difference between using the diaphragm valve’s full pulse and wasting most of it.
Supplied complete. Unlike the clamp-on aluminium nozzles, this assembly includes the nozzle, pipe adaptor, nozzle insert and lockring. Drill the insert to the orifice size your system needs before fitting.
Fitting: prepare 34.1 – 34.5 mm holes in the blowtube and deburr them. Assemble insert, pipe adaptor and lockring, screwing the insert only part way into the nozzle. Align the insert lugs along the axis of the blowtube and hook one lug into the hole, swing the second lug up and slide the pipe adaptor onto the tube, then screw the nozzle up onto the insert – hand tight is enough. Finally dent the lockring into one or both nozzle cavities to lock the assembly; to remove it later, bend the dent back out with a screwdriver blade.
Setting the nozzle height. For best performance set H, the distance from the nozzle to the filter, using H = (Ø Filter − 48) / 0.353 in mm, or H = (Ø Filter − 1.88) / 0.353 in inches.
Not for gas turbine applications. Goyen specifically excludes the GOCO nozzle range from gas turbine service.
Other barrel length in 2.5″: Goyen VNA62I-100 Blowtube Nozzle
Cartridge filters:
- Goyen CC100 Cartridge Cleaning Cone
- Goyen CC150 Cartridge Cleaning Cone
- Goyen CC200 Cartridge Cleaning Cone
Listed in the Goyen GOCO Blowtube Nozzles and Cartridge Cleaning Cones product leaflet.