Product Type: Filter Cleaning Sequencer / Timer Board

Series: ISP – Integrato Sequencer

Cleaning Mode: Demand driven – built-in differential pressure sensor

dP Support: 0 to 4.5 kPa

Input Voltage: 100/240 V AC @ 50/60 Hz

Output Voltage: 24 V DC

Maximum Input Power: 65 W

Discrete Solenoid Outputs: 12

Number of Terminals: 12

Enclosure: None – board only

Protection Rating: Board only – housing by others

Operating Temperature: -40°C to 60°C (-40°F to 140°F)

On & Off Time: ON: 30 ms to 1000 ms · OFF: 1 s to 1000 s

Inputs: Voltage free: Fan Stop, Low Header Alarm

Outputs: Voltage free: Coil Error · Analogue output: 4-20 mA dP signal

Diagnostics: Automatic valve detection, plus a visual display indication of which pilot output has an error

PCB Dimensions: 171.5 mm x 127 mm (6.75" x 5.00"), mounting centres 165 mm x 117.5 mm (6.50" x 4.63"), Ø5 mm (0.20") holes

Suitable For: Bags, cartridges, sintered metal and ceramic filters

Conforms To: UL, CE, FCC and RCM

SKU ISP-DC12 Category

Description

This replacement Goyen ISP-DC12 Integrato Sequencer was designed to the same specifications and is guaranteed to fit/perform as well as the OEM

*All filters and items marked replacement are not affiliated or associated with the original manufacture. Part numbers and names are used for cross reference only.

All valve and repair kits are backed by a 100% money back guarantee against defects in materials and workmanship. In the event of a product failure, we will replace the affected kit at no additional cost.

For Genuine Goyen Valves and Parts please call 562-436-4228 or email us at info@industrialfiltrationinc.com

The Integrato Sequencer is an integrated control for larger reverse pulse jet filter cleaning systems, built to work across a wide range of environmental conditions. This board has 12 solenoid outputs, 24 V DC output and no enclosure – board only.

The ISP has a built-in differential pressure sensor, so cleaning is demand driven and the filters are pulsed only when the pressure drop calls for it.

Pilot valves in parallel: this board drives 12 outputs directly; the IS/ISP family goes up to 40. Each AC output can drive 10 pilot valves in parallel, so a 40 output AC board supports up to 400 pilots. Each DC output can drive 3 in parallel between -20°C and 60°C (up to 120 pilots), or 2 in parallel between -40°C and 60°C (up to 80 pilots).

Order code: model – output voltage – number of terminals – enclosure type. This one is ISP (with dP sensor), DC output, 12 terminals, none – board only.

Continuous mode version: Goyen IS-DC12 Integrato Sequencer

Display module: Goyen ISD Display Module

Reviews

There are no reviews yet.

Be the first to review “Goyen ISP-DC12 Integrato Sequencer Timer Board – 12 Output – With dP Sensor – DC Output – No Enclosure”

contact us

Products

search

Industrial Filtration Inc logo

Request A Quote

To request a quote, enter the filter part #, along with a brief description of what you are looking for (optional), then hit 'Request quote'. Thank you for the opportunity to quote.

or try to find it on our website